FDD315 SERIES

FDD315 SERIES 1/8
HYDRAULIC DIVISION FDD315 SERIES
FDD315 SERIES
Duplex high pressure filters
Inline filters for operating pressure up to 315 bar, flow rate up to 280
l/min. Duplex construction for uninterrupted service. Change over valve
on upstream side, ergonomic switch-over handle with safety lock and
pressure compensation. Filter elements sizes according to DIN 24550
TECHNICAL INFORMATION
PRESSURE: max operating 315 bar sizes 040 to 100
max operating 200 bar sizes 160 to 400
CONNECTION PORTS: G1 sizes 040 to 100
G1 ½ sizes 160-250
DN38 (SAE Flange 1”1/2 3000 psi/M) size 400
MATERIALS: Filter head: cast iron
Filter bowl : steel
seals: NBR 
BYPASS setting 7 bar
ELECTRICAL CLOGGING INDICATOR: setting 5 bar
FILTER MEDIA: glassfiber G03 - G06 - G10 - G25
DIFFERENTIAL COLLAPSE PRESSURE: 20 bar or 210 bar
HOUSING
ELEMENT
OPERATING TEMPERATURE RANGE: -25°C +100°C 
FLUID COMPATIBILITY: Full with HH-HL-HM-HV (acc. To ISO 2943).
For use with other fluid please contact Filtrec Customer Service
(info@filtrec.it).
HYDRAULIC DIVISION FDD315 SERIES
FDD315 SERIES 2/8
OVERALL DIMENSIONS
*1 Venting screws
*2 Lever locking and arresting
Connection DN 38
MODEL B1 B2 B3 B4 D L1 L2 L3 L4 L5 L6 H1 H2 H3 A/F R kg
FDD315XD040 
100 55 M8 10 G 1" 182 90 140 66 86
78
285 228
38 27 80
10,5
FDD315XD063 345 288 12
FDD315XD100 427 370 14
FDD315XD160 
210 62 M12 28 G 1 1/2" 280 140 160 110 136
363 311
50
30
110
30
FDD315XD250 463 412 35
FDD315XD400 DN 38 614 562 20 41
Ø L4
FDD315 SERIES 3/8
HYDRAULIC DIVISION FDD315 SERIES
ORDERING INFORMATION
1. FILTER SERIES
4. FILTER MEDIA
8. BYPASS VALVE
6. SEALS
7. CONNECTIONS
9. INDICATOR PORT OPTION
10. INDICATOR
1. 2. 3. 4. 5. 6. 7. 8. 9. 10.
FDD315 XD 100 G10 A B B5 D W FG5
XD 100 G10 A
FDD315
2. FILTER ELEMENT SERIES XD
3. FILTER SIZE 040-063-100
160-250-400
B5 G 1” 
B7 G 1 1/2” 
38 1” 1/2 SAE 3000 psi/m
5. ELEMENT COLLAPSE A 21 bar
B 210 bar
W standard
FV5 differential visual 5 bar
FG5 differential electrical 5 bar
000 no element
G03 glassfiber ß4,5µm(c) > 1.000
G06 glassfiber ß7µm(c) > 1.000
G10 glassfiber ß12µm(c) > 1.000
G25 glassfiber ß22µm(c) > 1.000
0 no by-pass
D 7 bar
B NBR
recommended with by-pass option
for sizes 040-063-100
for sizes 160-250
for sizes 400
SPARE ELEMENT
PRESSURE DROP (∆p) INFORMATION FOR FILTER SIZING
HOUSING PRESSURE DROP
FDD315 XD040-063-100 FDD315 XD160-250-400
The total Delta P through a filter assembly is given from Housing ∆p + Element ∆p.
N.B. All the reported data have been obtained at our laboratory, according to specification ISO3968 with
mineral oil having 32 cSt viscosity and density 0,875 Kg/dm3.
The housing ∆p is given by the curve of the considered model and port, in correspondence of the flow rate value.
ELEMENT PRESSURE DROP 
The element ∆p (bar) is given by the flow rate (l/min) multiplied by the factor in the table here below corresponding to the selected media and divided by 1000.
If the oil has a viscosity Vx different than 32 cSt a corrective factor Vx/32 must be applied.
Example: 40 l/min with XD040G10A and oil viscosity 46 cSt > 40 x 8,75/1000 x 46/32 = 0,50 bar
EXAMPLE OF TOTAL ∆p CALCULATION
FDD315XD040G10ABB5BWFG5 with 40 l/min and oil 46 cSt:
Housing ∆p 0,38 bar + element Dp 0,50 bar (40 x 8,75/1000 x 46/32) = total assembly ∆p 0,88 bar
HYDRAULIC DIVISION FDD315 SERIES
FDD315 SERIES 4/8
G03A G06A G10A G25A
XD040 22,00 15,00 8,75 6,25
XD063 16,15 10,00 6,15 4,62
XD100 12,00 6,50 4,00 3,00
XD160 7,81 4,96 2,92 1,66
XD250 5,20 2,90 1,86 0,96
XD400 3,25 1,69 1,24 0,64
FDD315 SERIES 5/8
HYDRAULIC DIVISION FDD315 SERIES
ELEMENT PRESSURE DROP (filter elements 210 bar collapse)
The element ∆p (bar) is given by the flow rate (l/min) multiplied by the factor in the table here below 
corresponding to the selected media and divided by 1000.
If the oil has a viscosity Vx different than 32 cSt a corrective factor Vx/32 must be applied.
Example: 40 l/min with XD040G10B and oil viscosity 46 cSt > 40 x 16,25/1000 x 46/32 = 0,93 bar
G03B G06B G10B G25B
XD040 34,97 25,00 16,25 11,25
XD063 29,23 18,46 11,54 7,69
XD100 19,00 11,50 7,50 5,50
XD160 8,13 5,00 3,75 2,50
XD250 5,40 3,40 2,80 2,00
XD400 3,38 2,16 1,75 1,13
EXAMPLE OF TOTAL ∆p CALCULATION
FDD315XD040G10BBB5BWFG5 with 40 l/min and oil 46 cSt:
Housing ∆p 0,38 bar + element Dp 0,93 bar (40 x 16,25/1000 x 46/32) = total assembly ∆p 1,31 bar
N.B. All the reported data have been obtained at our laboratory, according to specification ISO3968 with mineral oil
having 32 cSt viscosity and density 0,875 Kg/dm3.
HYDRAULIC DIVISION FDD315 SERIES
FDD315 SERIES 6/8
USER TIPS
The filter element that can be replaced is in the side opposite to the switch-over handle (a label on the handle show it).
When the indicator shows and the filter element must be replaced, the flow must be diverted to the clean element acting
with the switch-over handle.
Follow carefully the instructions given in the User Handbook.
N.B. in case of cold start the indicator could give a false alarm: wait for the operating temperature to be reached and
press down the red pop-up button. If at this stage the red button pops up again and the electrical signal does not switch
off the filter element must be replaced.
The electrical indicator is supplied with normally closed contacts. The switching function may be changed to normally
open contacts by turning the electric upper part by 180°.
For any further information please contact our Customer Service (info@filtrec.it)

Technical information may change without notice
CT87-rev.00-05/20
www.filtrec.com
HYDRAULIC DIVISION FDD315 SERIES
FDD315 SERIES 8/8