FDD040 SERIES

FDD040 SERIES 1/8
HYDRAULIC DIVISION FDD040 SERIES
FDD040 SERIES
Duplex low pressure filters
Sizes 630 to 1000 according to DIN 24550
Inline filters for operating pressure up to 40 bar, flow rate up to 
1000 l/min. 
Duplex construction for uninterrupted service. Change over valve
on upstream side, ergonomic switch-over handle with safety lock and
pressure compensation. 
TECHNICAL INFORMATION
PRESSURE: max operating 40 bar 
CONNECTION PORTS: DN 64 (SAE fl. 2 1/2" 3000 psi)
MATERIALS: filter head : cast iron GGG
filter bowl : steel
seals: NBR 
BYPASS setting 3,5 bar
ELECTRICAL CLOGGING INDICATOR: setting 2,2 bar
FILTER MEDIA: glassfiber G03 - G06 - G10 - G25
DIFFERENTIAL COLLAPSE PRESSURE: 20 bar or 210 bar
HOUSING
ELEMENT
OPERATING TEMPERATURE RANGE: -25°C +100°C 
FLUID COMPATIBILITY: Full with HH-HL-HM-HV (acc. To ISO 2943).
For use with other fluid please contact Filtrec Customer Service
(info@filtrec.it).
HYDRAULIC DIVISION FDD040 SERIES
FDD040 SERIES 2/8
OVERALL DIMENSIONS
MODEL D H1 R kg
FDD040XD630 
DN 64 (SAE fl. 2 1/2" 3000 psi)
690 300 80
FDD040XD1000 920 530 100 H1
*1 R element removal
*2 Pressure equalization valve
*3 Drain screw G¼
*4 Clogging indicator
*5 Vent screw
IN & OUT ports
DN 64 (SAE fl. 2 1/2" 3000 psi)
R
FDD040 SERIES 3/8
HYDRAULIC DIVISION FDD040 SERIES
ORDERING INFORMATION
1. FILTER SERIES
4. FILTER MEDIA
8. BYPASS VALVE
6. SEALS
7. CONNECTIONS
9. INDICATOR PORT OPTION
10. INDICATOR
1. 2. 3. 4. 5. 6. 7. 8. 9. 10.
FDD040 XD 1000 G10 A B 64 D W FG2
XD 1000 G10 A
FDD040
2. FILTER ELEMENT SERIES XD
3. FILTER SIZE 630 - 1000
64 DN 64 (SAE fl. 2 1/2" 3000 psi)
5. ELEMENT COLLAPSE A 21 bar
B 210 bar
W standard
FV2 differential visual 2,2 bar
FG2 differential electrical 2,2 bar
000 no element
G03 glassfiber ß4,5µm(c) > 1.000
G06 glassfiber ß7µm(c) > 1.000
G10 glassfiber ß12µm(c) > 1.000
G25 glassfiber ß22µm(c) > 1.000
0 no by-pass
D 3,5 bar
B NBR
recommended with by-pass option
SPARE ELEMENT
PRESSURE DROP (∆p) INFORMATION FOR FILTER SIZING
HOUSING PRESSURE DROP
FDD040 XD630- 1000
The total Delta P through a filter assembly is given from Housing ∆p + Element ∆p.
N.B. All the reported data have been obtained at our laboratory, according to specification ISO3968 with
mineral oil having 32 cSt viscosity and density 0,875 Kg/dm3.
The housing ∆p is given by the curve of the considered model and port, in correspondence of the flow rate value.
ELEMENT PRESSURE DROP (filter elements 20 bar collapse)
The element ∆p (bar) is given by the flow rate (l/min) multiplied by the factor in the table here below corresponding to the selected media and divided by 1000.
If the oil has a viscosity Vx different than 32 cSt a corrective factor Vx/32 must be applied.
Example: 400 l/min with XD1000G10A and oil viscosity 46 cSt > 400 x 1,00/1000 x 46/32 = 0,58 bar
EXAMPLE OF TOTAL ∆p CALCULATION
FDD040XD1000G10ABB5BWFG2 with 400 l/min and oil 46 cSt:
Housing ∆p 0,15 bar + element Dp 0,58 bar (400 x 1,00/1000 x 46/32) = total assembly ∆p 0,73 bar
HYDRAULIC DIVISION FDD040 SERIES
FDD040 SERIES 4/8
G03A G06A G10A G25A
XD630 2,14 1,32 0,87 0,63
XD1000 1,46 0,91 0,60 0,43
FDD040 SERIES 5/8
HYDRAULIC DIVISION FDD040 SERIES
ELEMENT PRESSURE DROP (filter elements 210 bar collapse)
The element ∆p (bar) is given by the flow rate (l/min) multiplied by the factor in the table here below 
corresponding to the selected media and divided by 1000.
If the oil has a viscosity Vx different than 32 cSt a corrective factor Vx/32 must be applied.
Example: 400 l/min with XD1000G10B and oil viscosity 46 cSt > 400 x 1,20/1000 x 46/32 = 0,69 bar
G03B G06B G10B G25B
XD630 2,65 1,63 1,08 0,78
XD1000 1,81 1,13 0,74 0,53
EXAMPLE OF TOTAL ∆p CALCULATION
FDD040XD1000G10BBB5BWFG2 with 400 l/min and oil 46 cSt:
Housing ∆p 0,15 bar + element Dp 0,69 bar (400 x 1,20/1000 x 46/32) = total assembly ∆p 0,84 bar
N.B. All the reported data have been obtained at our laboratory, according to specification ISO3968 with mineral oil
having 32 cSt viscosity and density 0,875 Kg/dm3.
HYDRAULIC DIVISION FDD040 SERIES
FDD040 SERIES 6/8
USER TIPS
The filter element that can be replaced is in the side opposite to the switch-over handle (a label on the handle show it).
When the indicator shows and the filter element must be replaced, the flow must be diverted to the clean element acting
with the switch-over handle (after having equalized the pressure though the manual valve, as described in detail in the
user handbook).
Follow carefully the instructions given in the User Handbook.
N.B. in case of cold start the indicator could give a false alarm: wait for the operating temperature to be reached and
press down the red pop-up button. If at this stage the red button pops up again and the electrical signal does not switch
off the filter element must be replaced.
The electrical indicator is supplied with normally closed contacts. The switching function may be changed to normally
open contacts by turning the electric upper part by 180°.
For any further information please contact our Customer Service (info@filtrec.it)

Technical information may change without notice
CT89-rev.00-08/20
www.filtrec.com