F160 SERIES

HYDRAULIC DIVISION F160 SERIES
F160 SERIES
In line high pressure filters
elements according to DIN 24550
TECHNICAL INFORMATION
Inline filters for operating pressure up to 160 bar, flow rate up to 400 l/min.
Available with or without bypass, indicator port is a standard option to fit a
visual or electrical differential indicator.
F160 SERIES 1/8
HYDRAULIC SYMBOL:
PRESSURE: Max operating: 160 bar 
Burst: 480 bar
CONNECTION PORTS: G 1/2”÷1 1/2” 
MATERIALS: Head: cast iron
Bowl: aluminium alloy 
Seal: NBR (FKM on request)
BYPASS: No by-pass or 6 bar setting
FILTER MEDIA: Inorganic microfiber: G03 - G06 - G10 - G15 - G25
Paper: C10
DIFFERENTIAL COLLAPSE PRESSURE: 21 bar or 210 bar
OPERATING TEMPERATURE RANGE: -25°C +100°C 
FLUID COMPATIBILITY: Full with HH-HL-HM-HV (acc. To ISO 2943).
For use with other fluid please contact Filtrec Customer Service
(info@filtrec.it).
HOUSING
ELEMENT type DIN 24550, tested according to ISO 2941, 2942, 2943, 3968, 16889, 23181
tested according to NFPA T3.10.5.1 , ISO3968
F160 SERIES 2/8
 
 
4+1 HOLES
= =
= =
B6
3 HOLES
Ø F x Depth
Ø F x Depth
Indicator port
option S Indicator port
option S
A
A
L1
B3 B2
= =
B6
B4
B2
B5
B5
B1
H2
30
D1
H1
R element removal
OVERALL DIMENSIONS
NOMINAL SIZE
HYDRAULIC DIVISION F160 SERIES
MODEL A B1 B2 B3 B4 B5 B6 D1 F H1 H2 L1 R WEIGHT
F160-XD040 G 1/2” 
G 3/4”
G 1”
22,5 47,5 43,5 27,5
25 60,6
65
M10x15
180
92 90 110
2,4 Kg
F160-XD063 250 2,6 Kg
F160-XD100 329 2,8 Kg
F160-XD160
G 1 1/4”
G 1 1/2” 40 55 --- --- 110
289
129 140 130
6,6 Kg
F160-XD250 361 7 Kg
F160-XD400 514 10 Kg
F160-XD160/250/400
F160 SERIES 3/8
HYDRAULIC DIVISION F160 SERIES
ORDERING INFORMATION
1. FILTER SERIES
4. FILTER MEDIA
8. BYPASS VALVE
6. SEALS
7. CONNECTIONS
9. INDICATOR PORT OPTION
10. INDICATOR
1. 2. 3. 4. 5. 6. 7. 8. 9. 10.
F160 XD 100 G10 A B B3 D W E05
XD 100 G10 A
F160
2. FILTER ELEMENT SERIES XD
3. FILTER SIZE 040-063-100
160-250-400
B3 G 1/2” 
B4 G 3/4” 
B5 G 1” 
B6 G 1 1/4” 
B7 G 1 1/2” 
5. ELEMENT COLLPASE A 21 bar
B 210 bar
S with metal plug
W with plastic plug
000 no indicator
V05 differential visual 5 bar
E05 differential electrical 5 bar
V08 differential visual 8 bar
E08 differential electrical 8 bar
000 no element
G03 glassfiber ß4,5µm(c) > 1.000
G06 glassfiber ß7µm(c) > 1.000
G10 glassfiber ß12µm(c) > 1.000
G15 glassfiber ß18µm(c) > 1.000
G25 glassfiber ß22µm(c) > 1.000
C10 paper ß10µm(c) > 2
0 no by-pass
D 6 bar
B NBR
V FKM
only for Dp 21 bar
recommended with no by-pass option
no bypass version only
for sizes 160-250-400
when using an indicator
For different thread options please check for sizes 040-063-100
availability with Filtrec Customer Service.
SPARE ELEMENT
ACCESSORIES LC24 LED connector 
The accessories must be ordered
separately
F160 SERIES 4/8
HYDRAULIC DIVISION F160 SERIES
PRESSURE DROP (∆p) INFORMATION FOR FILTER SIZING
HOUSING PRESSURE DROP
F160 XD040-063-100 F160 XD160-250-400
The total Delta P through a filter assembly is given from Housing ∆p + Element ∆p.
This ideally should not exceed 1,0 bar and should never exceed 1/3 of the set value of the by-pass valve.
N.B. All the reported data have been obtained at our laboratory, according to specification ISO3968 with
mineral oil having 32 cSt viscosity and density 0,875 Kg/dm3.
The housing ∆p is given by the curve of the considered model and port, in correspondence of the flow rate value.
ELEMENT PRESSURE DROP (filter elements 21 bar collapse)
The element ∆p (bar) is given by the flow rate (l/min) multiplied by the factor in the table here below corresponding to the selected media and divided by 1000.
If the oil has a viscosity Vx different than 32 cSt a corrective factor Vx/32 must be applied.
Example: 80 l/min with XD063G25A and oil viscosity 46 cSt > 80 x 4,62/1000 x 46/32 = 0,53 bar
EXAMPLE OF TOTAL ∆p CALCULATION
F160XD063G25ABB5DWV05 with 80 l/min and oil 46 cSt:
Housing ∆p 0,3 bar + element Dp 0,53 bar (80 x 4,62/1000 x 46/32) = total assembly ∆p 0,83 bar
G03A G06A G10A G15A G25A C10A
XD040 22,00 15,00 8,75 7,50 6,25 5,00
XD063 16,15 10,00 6,15 5,38 4,62 3,85
XD100 12,00 6,50 4,00 3,50 3,00 2,00
XD160 7,81 4,96 2,92 2,04 1,66 0,94
XD250 5,20 2,90 1,86 1,01 0,96 0,58
XD400 3,25 1,69 1,24 0,71 0,64 0,36
Flow rate (l/min)
∆p (bar)
Flow rate (l/min)
∆p (bar)
F160 SERIES 5/8
ELEMENT PRESSURE DROP (filter elements 210 bar collapse)
The element ∆p (bar) is given by the flow rate (l/min) multiplied by the factor in the table here below 
corresponding to the selected media and divided by 1000.
If the oil has a viscosity Vx different than 32 cSt a corrective factor Vx/32 must be applied.
Example: 80 l/min with XD100G25B and oil viscosity 46 cSt > 80 x 5,5/1000 x 46/32 = 0,63 bar
G03B G06B G10B G15B G25B
XD040 34,97 25,00 16,25 13,75 11,25
XD063 29,23 18,46 11,54 9,62 7,69
XD100 19,00 11,50 7,50 6,50 5,50
XD160 8,13 5,00 3,75 3,13 2,50
XD250 5,40 3,40 2,80 2,40 2,00
XD400 3,38 2,16 1,75 1,44 1,13
EXAMPLE OF TOTAL ∆p CALCULATION
F160XD100G25BBB5DWV08 with 80 l/min and oil 46 cSt :
Housing ∆p 0,3 bar + element Dp 0,63 bar (80 x 5,5/1000 x 46/32) = total assembly ∆p 0,93 bar
N.B. All the reported data have been obtained at our laboratory, according to specification ISO3968 with mineral oil
having 32 cSt viscosity and density 0,875 Kg/dm3.
BYPASS VALVE PRESSURE DROP
The bypass valve ∆p is given by the curve of the considered model and setting, in correspondence of the flow rate
value.
F160 XD040-063-100 F160 XD160-250-400
Flow rate (l/min)
∆p (bar)
Flow rate (l/min)
∆p (bar)
HYDRAULIC DIVISION F160 SERIES
USER TIPS INSTALLATION
1
2
3 3 3 1
6
7
8
5
4
FILTER HEAD
2 INDICATOR PORT
3 FIXING HOLES
4 BY- PASS VALVE
5 FILTER ELEMENT
6 FILTER BOWL
7 SEAL KIT
8 IDENTIFICATION LABEL
1. the IN and OUT ports must be connected to the
hoses in the correct flow direction (an arrow
shows on the filter head (1) 
2. the filter housing should be preferably mounted
with the bowl (6) downward
3. secure to the frame the filter head (1) using the
threaded fixing holes (3)
4. verify that no tension is present on the filter after
mounting
5. enough space must be available for filter
element replacement
6. the visual clogging indicator must be in a easily
viewable position
7. when a electrical indicator is used, make sure
that it is properly wired
8. never run the system with no filter element fitted
9. keep in stock a spare FILTREC filter element for
timely replacement when required
OPERATION
1. the filter must work within the operating
conditions of pressure, temperature and
compatibility given in the first page of this data
sheet
2. the filter element must be replaced as soon as
the clogging indicator signals at working
temperature (in cold start conditions, oil
temperature lower than 30°C, a false alarm can
be given due to oil viscosity)
3. If no clogging indicator is mounted, replace the
element according to the system manufacturer’s
recommendations 
WARNING
Make sure that Personal Protective Equipment (PPE) is
worn during installation and maintenance operation. 
DISPOSAL OF FILTER ELEMENT
The used filter elements and the filter parts dirty of oil
are classified as “Dangerous waste material”: they
must be disposed according to the local laws by
authorized Companies.
MAINTENANCE
1. make sure that the system is switched off and
there is no residual pressure in the filter
2. unscrew the bowl (6) by turning it anti-clockwise
and remove it
3. remove the dirty element (5)
4. fit a new FILTREC element (5), verifying the part
number, particularly concerning the micron
rating; open its plastic protection on the open
end side and insert it onto the spigot in the filter
head, then remove completely the plastic
protection
5. clean carefully the bowl; check the O-rings (7) 
conditions and replace if necessary
6. lubricate the bowl's thread (6) and screw it by
hand in the filter head (1) by turning it
clockwise
7. screw in the bowl to stop
8. the used filter elements cannot be cleaned
and re-used
INDICATOR TIGHTENING TORQUE
V05/E05/V08/E08 50 Nm
SPARE SEAL KIT PART NUMBER
NBR FKM
F160 XD040-063-100 06.021.00090 06.021.00135
F160 XD160-250-400 06.021.00096 06.021.00114
F160 SERIES 6/8
HYDRAULIC DIVISION F160 SERIES
3

CT53-rev.00-05/20
Technical information may change without notice
HYDRAULIC DIVISION F160 SERIES
F160 SERIES 8/8