F040 SERIES

HYDRAULIC DIVISION F040 SERIES
F040 SERIES
In line medium pressure filters
TECHNICAL INFORMATION
Inline filters for operating pressure up to 70 bar, flow rate up to 400 l/min.
Available with or without bypass, indicator port is a standard option to fit a
visual or electrical differential indicator.
F040 SERIES 1/8
HYDRAULIC SYMBOL:
PRESSURE: Max operating: F040 DMD0005-8-11 70 bar 
F040 DMD0015-30-45 40 bar 
Burst: F040 DMD0005-8-11 210 bar
F040 DMD0015-30-45 120 bar
CONNECTION PORTS: G 3/4”÷1 1/4” 
MATERIALS: Head: aluminium alloy
Bowl: aluminium alloy 
Seal: NBR (FKM on request)
BYPASS: No by-pass or 3,5 bar setting
FILTER MEDIA: Inorganic microfiber: E01- E03 - E05 - E10 - E15 - E20
Paper: D10
DIFFERENTIAL COLLAPSE PRESSURE: 30 bar
OPERATING TEMPERATURE RANGE: -25°C +100°C 
FLUID COMPATIBILITY: Full with HH-HL-HM-HV (acc. To ISO 2943).
For use with other fluid please contact Filtrec Customer Service
(info@filtrec.it).
HOUSING
ELEMENT tested according to ISO 2941, 2942, 2943, 3968, 16889, 23181
tested according to NFPA T3.10.5.1 , ISO3968
F040 SERIES 2/8
R Element removal
==
B4
B3
2 Holes Indicator port
Ø F x Depth
L1
A
A
H1
D1
30
B1 B2
 
H2
OVERALL DIMENSIONS
NOMINAL SIZE
HYDRAULIC DIVISION F040 SERIES
MODEL A B1 B2 B3 B4 D1 F H1 H2 L1 R WEIGHT
F040-DMD0005
G 3/4” 19 28 15 45 65 M8x12
160
100 95 110
1,0 Kg
F040-DMD0008 238 1,3 Kg
F040-DMD0011 312 1,6 Kg
F040-DMD0015
G 1 1/4” 30 24 109 M12x18
230
124 150 130
2,9 Kg
F040-DMD0030 26 60 343 3,9 Kg
F040-DMD0045 461 4,9 Kg
F040 SERIES 3/8
HYDRAULIC DIVISION F040 SERIES
ORDERING INFORMATION
1. FILTER SERIES
4. FILTER MEDIA
7. BYPASS VALVE
5. SEALS
6. CONNECTIONS
8. INDICATOR PORT OPTION
9. INDICATOR
1. 2. 3. 4. 5. 6. 7. 8. 9.
F040 DMD 0015 E10 B B4 D W E02
DMD 0015 E10 B
F040
2. FILTER ELEMENT SERIES DMD
3. FILTER SIZE 0005-0008-0011
0015-0030-0045
B4 G 3/4” 
B6 G 1 1/4” 
S with metal plug
W with plastic plug
000 no indicator
V02 differential visual 2,7 bar
E02 differential electrical 2,7 bar
V05 differential visual 5 bar
E05 differential electrical 5 bar
000 no element
E01 glassfiber ß4 µm(c) > 1.000
E03 glassfiber ß5µm(c) > 1.000
E05 glassfiber ß7µm(c) > 1.000
E10 glassfiber ß12µm(c) > 1.000
E15 glassfiber ß17µm(c) > 1.000
E20 glassfiber ß22µm(c) > 1.000
D10 paper ß10µm(c) > 2
0 no by-pass
D 3,5 bar
B NBR
V FKM
no bypass version only
for sizes 0015-0030-0045
when using an indicator
for sizes 0005-0008-0011 
SPARE ELEMENT
ACCESSORIES LC24 LED connector 
The accessories must be ordered
separately
F040 SERIES 4/8
HYDRAULIC DIVISION F040 SERIES
PRESSURE DROP (∆p) INFORMATION FOR FILTER SIZING
HOUSING PRESSURE DROP
F040DMD0005-0008-0011 F040DMD0015-0030-0045
The total Delta P through a filter assembly is given from Housing ∆p + Element ∆p.
This ideally should not exceed 1,0 bar and should never exceed 1/3 of the set value of the by-pass valve.
N.B. All the reported data have been obtained at our laboratory, according to specification ISO3968 with
mineral oil having 32 cSt viscosity and density 0,875 Kg/dm3.
The housing ∆p is given by the curve of the considered model and port, in correspondence of the flow rate value.
ELEMENT PRESSURE DROP 
The element ∆p (bar) is given by the flow rate (l/min) multiplied by the factor in the table here below corresponding to the selected media and divided by 1000.
If the oil has a viscosity Vx different than 32 cSt a corrective factor Vx/32 must be applied.
Example: 60 l/min with DMD0011E10B and oil viscosity 46 cSt > 60 x 5,10/1000 x 46/32 = 0,44 bar
EXAMPLE OF TOTAL ∆p CALCULATION
F040DMD0011BB4DWV05 with 60 l/min and oil 46 cSt:
Housing ∆p 0,27 bar + element Dp 0,44 bar (60 x 5,10/1000 x 46/32) = total assembly ∆p 0,71 bar
Flow rate (l/min)
∆p (bar)
Flow rate (l/min)
∆p (bar)
E01B E03B E06B E10B E15B E20B D10B
DMD0005 49,98 34,99 29,14 17,71 12,16 10,67 8,84
DMD0008 30,99 21,69 12,56 9,00 5,92 4,99 3,56
DMD0011 22,17 15,52 9,30 5,10 3,75 3,15 2,58
DMD0015 10,55 7,39 4,25 2,40 1,68 1,20 1,04
DMD0030 5,62 3,93 2,57 1,18 0,93 0,72 0,63
DMD0045 3,48 2,43 1,53 0,99 0,68 0,50 0,48
F040 SERIES 5/8
N.B. All the reported data have been obtained at our laboratory, according to specification ISO3968 with mineral oil
having 32 cSt viscosity and density 0,875 Kg/dm3.
BYPASS VALVE PRESSURE DROP
The bypass valve ∆p is given by the curve of the considered model and setting, in correspondence of the flow rate
value.
F040DMD0005-0008-0011 F040DMD0015-0030-0045
Flow rate (l/min)
∆p (bar)
Flow rate (l/min)
∆p (bar)
HYDRAULIC DIVISION F040 SERIES
USER TIPS INSTALLATION
1
2
3 1
6
7
7
8
5
4
FILTER HEAD
2 INDICATOR PORT
3 FIXING HOLES
4 BY- PASS VALVE
5 FILTER ELEMENT
6 FILTER BOWL
7 SEAL KIT
8 IDENTIFICATION LABEL
1. the IN and OUT ports must be connected to the
hoses in the correct flow direction (an arrow
shows on the filter head (1) 
2. the filter housing should be preferably mounted
with the bowl (6) downward
3. secure to the frame the filter head (1) using the
threaded fixing holes (3)
4. verify that no tension is present on the filter after
mounting
5. enough space must be available for filter
element replacement
6. the visual clogging indicator must be in a easily
viewable position
7. when a electrical indicator is used, make sure
that it is properly wired
8. never run the system with no filter element fitted
9. keep in stock a spare FILTREC filter element for
timely replacement when required
OPERATION
1. the filter must work within the operating
conditions of pressure, temperature and
compatibility given in the first page of this data
sheet
2. the filter element must be replaced as soon as
the clogging indicator signals at working
temperature (in cold start conditions, oil
temperature lower than 30°C, a false alarm can
be given due to oil viscosity)
3. If no clogging indicator is mounted, replace the
element according to the system manufacturer’s
recommendations 
WARNING
Make sure that Personal Protective Equipment (PPE) is
worn during installation and maintenance operation. 
DISPOSAL OF FILTER ELEMENT
The used filter elements and the filter parts dirty of oil
are classified as “Dangerous waste material”: they
must be disposed according to the local laws by
authorized Companies.
MAINTENANCE
1. make sure that the system is switched off and
there is no residual pressure in the filter
2. unscrew the bowl (6) by turning it anti-clockwise
and remove it
3. remove the dirty element (5)
4. fit a new FILTREC element (5), verifying the part
number, particularly concerning the micron
rating; open its plastic protection on the open
end side and insert it onto the spigot in the filter
head, then remove completely the plastic
protection
5. clean carefully the bowl; check the O-rings (7) 
conditions and replace if necessary
6. lubricate the bowl's thread (6) and screw it by
hand in the filter head (1) by turning it
clockwise
7. screw in the bowl to stop
8. the used filter elements cannot be cleaned
and re-used
INDICATOR TIGHTENING TORQUE
V02/E02/V05/E05 50 Nm
BOWL TIGHTENING TORQUE
F040 DMD005/8/11 40 Nm
F040 DMD0015/30/45 60 Nm
SPARE SEAL KIT PART NUMBER
NBR FKM
F040 DMD005/8/11 06.021.00127 06.021.00128
F040 DMD0015/30/45 06.021.00129 06.021.00130
F040 SERIES 6/8
HYDRAULIC DIVISION F040 SERIES

CT64-rev.01-03/21
Technical information may change without notice F040 SERIES 8/8
HYDRAULIC DIVISION F040 SERIES